Gødstrup Hospital

Consultant for Grontmij (CURATIVA). Optimized design of driven concrete piles (30x30cm and 35x35cm) supporting bed-towers. Responsible for establishing load displacement curves for axially loaded piles in compression and tension including group effects, effect of relief during excavation and the time dependent increase in bearing capacity for piles in fine grained soils.

Location: Denmark, Herning

Client: Region Midtjylland Regionsrådet

Years: 2013 - 2014

Pile foundations